FAN MODEL
CFM
IN
RPM
WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
SEE REVERSE SIDE FOR STATIC PRESSURE RANGES
Grill
White, polymeric grill secured in place with torsion springs; easily removed
if necessary, dimensions - 17" x 15
7
/
8
".
Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a hex nut.
Adjustable Capacity Motor
8 capacity settings on low speed allow the fan to be set to the required
exhaust rate for continuous ventilation. Low speed set points include:
30 40 50 60 70 90 100 & 120 CFM
High speed rapidly clears the air of moisture, odors or other contaminants.
High speed set points include: 80 110 130 Boost
Quiet 4 Pole motor, suitable for continuous operation, permanently
lubricated, 115/120V 60 Hz., 0.30 amps. Ideal for compliance with
Ashrae 62.2, LEED, ENERGY STAR
®
for Homes, California Title 24 and
other programs.
Fan Housing
23 gauge galvanized steel housing. Overall dimensions: 12
7
/
8
"x 12
3
/
4
"x 9
7
/
8
".
Duct Collar
6" round, zinc plated metal collar adapter. Gasketed, spring loaded
aluminum backdraft damper.
Electrical Connections
0.5" electrical knockouts provided. Easy wiring access via either internal
or external wiring compartment cover.
Lighting
GU24 base, 8 Watt 4000K LED Lamp, 725 Lumens (91 Lumens/Watt)
4 watt night light (night light bulb not included).
Single Pack Shipping Info
Box Dim: 20" x 15
7
/
8
" x 11
3
/
8
"
Shipping Weight: 17 lbs.
Unit Mounting
The housing will mount through drywall thickness up to
3
/
4
", with a
rough-in opening of 13
1
/
8
" x 13". The housing will mount either between
16" or 24" on center joists, using the 2 supplied housing mounting
brackets. The housing mounting brackets can be adapted for overhead
mounting (hardware not provided). The unit is provided with an optionally
installed ceiling flange to ensure proper building infiltration rates are
maintained and that no air leaks occur between the fan housing and
ceiling cutout.
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
HIGHEST AVAILABLE SPEED: 150 CFM/0.6 Sones @ 0.10 SP.
LOWEST AVAILABLE SPEED: 30 CFM/<0.3 Sones @ 0.10" SP.
VARIABLE AIRFLOW DUAL SPEED
EXHAUST FAN
SPECIFICATIONS
EVLD
U.S.: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
V
E
N
T
I
L
A
T
I
O
N
S
T
A
N
D
A
R
D
S
62.2
ASHRAE
COMPLIES WITH
Updated 3-18
Canada:
Brampton, Ontario
Tel: 905-456-2033
Fax: (905) 456-1015
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - • Unit Mounting

127/8"123/4"97/8"17"157/8"6"Specifications subject to change without notice.PROJECTLOCATIONCONTRACTORARCHITECTENGINEERSU

Strona 2 - ACHIEVABLE STATIC PRESSURES

Specifications subject to change without notice.MEETS MADE IN AMERICAREQUIREMENTS OF ARRAMEETS MADE IN AMERICAREQUIREMENTS OF ARRAACHIEVABLE STATIC PR

Komentarze do niniejszej Instrukcji

Brak uwag