Air King EVDGH Arkusz Specyfikacji

Przeglądaj online lub pobierz Arkusz Specyfikacji dla Nie Air King EVDGH. Air King EVDGH Spec Sheet Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 2
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Specifications subject to change without notice.
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM
WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
SEE REVERSE SIDE FOR STATIC PRESSURE RANGES
Grill
White, polymeric grill secured in place with torsion springs; easily
removed if necessary, dimensions - 14
1
/
4
" x 14
1
/
4
".
Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a hex nut.
Adjustable Capacity Motor
8 capacity settings on low speed allow the fan to be set to the required
exhaust rate for continuous ventilation. Low speed set points include:
30 40 50 60 70 90 100 & 120 CFM
High speed rapidly clears the air of moisture, odors or other
contaminants. High speed set points include: 80 110 130 Boost
Quiet 4 Pole motor, suitable for continuous operation, permanently
lubricated, 115/120V 60 Hz., 0.30 amps. Ideal for compliance with
Ashrae 62.2, LEED, ENERGY STAR
®
for Homes, California Title 24 and
other programs.
Motion Sensor
Integrated motion sensor automatically turns fan to high speed when
room is occupied. Adjustable off delay from 30 seconds to 80 minutes.
Humidity Sensor
Integrated humidity sensor, adjustable up to 80% RH automatically
turns fan to high speed until humidity drops to the desired set point.
Fan Housing
23 gauge galvanized steel housing. Overall dimensions:
12
7
/
8
"x 12
3
/
4
"x 9
7
/
8
".
Duct Collar
6" round, zinc plated metal collar adapter. Gasketed, spring loaded
aluminum backdraft damper.
Electrical Connections
0.5" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
Single Pack Shipping Info
Box Dim: 20" x 15
7
/
8
" x 11
3
/
8
"
Shipping Weight: 17 lbs.
Unit Mounting
The housing will mount through drywall thickness up to
3
/
4
", with
a rough-in opening of 13
1
/
8
" x 13". The housing will mount either
between 16" or 24" on center joists, using the 2 supplied housing
mounting brackets. The housing mounting brackets can be
adapted for overhead mounting (hardware not provided). The unit
is provided with an optionally installed ceiling flange to ensure
proper building infiltration rates are maintained and that no air
leaks occur between the fan housing and ceiling cutout.
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
M
E
E
T
S
M
A
D
E
I
N
A
M
E
R
I
C
A
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
A
R
R
A
12
7
/
8
"
12
3
/
4
"
6"
9
7
/
8
"
14
1
/
4
"
14
1
/
4
"
VARIABLE AIRFLOW DUAL SPEED
EXHAUST FAN
SPECIFICATIONS
EVDGH
Updated 2-16
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
HIGHEST AVAILABLE SPEED: 150 CFM/0.6 Sones @ 0.10 SP.
LOWEST AVAILABLE SPEED: 30 CFM/<0.3 Sones @ 0.10" SP.
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - SPECIFICATIONS

Specifications subject to change without notice.PROJECTLOCATIONCONTRACTORARCHITECTENGINEERSUBMITTED BY DATE FAN MODEL CFM IN RPM WATTS AMPS SONES QT

Strona 2 - ACHIEVABLE STATIC PRESSURES

Specifications subject to change without notice.MEETS MADE IN AMERICAREQUIREMENTS OF ARRAMEETS MADE IN AMERICAREQUIREMENTS OF ARRAACHIEVABLE STATIC PR

Komentarze do niniejszej Instrukcji

Brak uwag